Get HP HPE2-T37 Dumps Questions [2022] To Gain Brilliant Result [Q16-Q39]

Share

Get HP HPE2-T37 Dumps Questions [2022] To Gain Brilliant Result

HPE2-T37 dumps - Prep4sures - 100% Passing Guarantee


HP HPE2-T37 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Describe industry standard data center infrastructure management technologies
Topic 2
  • Manage and report on Hybrid IT infrastructure using HPE OneView
Topic 3
  • Describe HPE OneView and its elements and positioning for customer business outcomes
Topic 4
  • Monitor and troubleshoot common Hybrid IT infrastructure issues using HPE OneView
Topic 5
  • Provision Hybrid IT infrastructure using HPE OneView
  • Install and configure HPE OneView and related elements

 

NEW QUESTION 16
Your customer plans to use HPE OneView to manage a small environment based on HPE ProLiant servers that includes G7 and Gen 10 systems. What should you explain to this customer?

  • A. Not all of the features will be available for HPE ProLiant G7 systems.
  • B. HPE ProLiant Gen 10 servers do not need an HPE OneView license.
  • C. HPE ProLiant G7 and Gen10 cannot be managed using the same appliance.
  • D. HPE Management Agent must he installed for for HPE ProLiant Gen 10 servers.

Answer: B

 

NEW QUESTION 17
You ate implementing an HPE Synergy solution with multiple frames in one management ring. Image Streamer is not a part of this solution. How can an IPv4 address pool defined by the administrator be used In HPE OneView?

  • A. to provide static IP addresses for Logical Interconnects and Logical Enclosures
  • B. to provide static IP addresses to IL0 and interconnect modules if applicable
  • C. to provide static IP addresses for an operating system running on a Compute Module
  • D. to provide static IP addresses for storage systems managed in HPE OneView

Answer: C

 

NEW QUESTION 18
Refer to the exhibit.

Which statement about the logical interconnect shown is true?

  • A. Additional uplink ports can be added to ETH-Uplink to increase available bandwidth.
  • B. The maximum supported number of the internal networks for logical interconnect is configured.
  • C. FC uplinks are not supported and will be converted to FCoE or RoCE uplinks.
  • D. For FC uplink sets, an additional uplink from second module should be added for redundancy.

Answer: A

 

NEW QUESTION 19
Your customer wants to manage their HPE Superdome Flex using HPE OneView.
Which component must be added to HPE OneView to accomplish this task?

  • A. Rack Management Controller (RMC)
  • B. only the base chassis from the complex
  • C. Baseboard Management Controller (BMC)
  • D. all nPARs created within the complex

Answer: C

 

NEW QUESTION 20
Click the option that will allow you to update the firmware of master and satellite modules.

Answer:

Explanation:

 

NEW QUESTION 21
Your customer is considering HPE Synergy as a hardware platform for visualization workload. The customer environment is wry dynamic, and they often have to modify hypervisor networking.
Which resource provided by HPE should you discuss with this customer?

  • A. HPE OneView for VMware vCenter Server will enable host profile functionality and simplify changes.
  • B. HPE OneView Global Dashboard allows server profile replication and change management.
  • C. HPE Image Streamer provides templates which can be updated to map the hypervisor requirements
  • D. PowerShell Library for HPE OneView allows scripted environment modification.

Answer: D

 

NEW QUESTION 22
You need to make sure that server ports connected to this network cannot communicate with each other within the logical interconnect. Click the option within the network definition that will allow you to configure the required parameter.

Answer:

Explanation:

 

NEW QUESTION 23
What step must be taken to add an HPE SuperDome Flex to an existing OneView environment

  • A. HPE Superdome Flex complex can be added by adding base chassis of this complex.
  • B. A Rack Management Controller must be added to HPE OneView.
  • C. HPE Superdome Flex can be added to HPE OneView after at least one nPAR is created.
  • D. Each HPE Superdome Flex chassis must be added Individually using BMC IP.

Answer: B

 

NEW QUESTION 24
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

Answer:

Explanation:

 

NEW QUESTION 25
Your customer runs VMware ESXi on an HPE Synergy platform. The ESXi systems must have access to 50 VLANs initially. However, this is a dynamic environment, and more VLANs will be added in the future.
They want to add more networks for virtual machines, but they do not want to modify the HPE Virtual Connect configuration.
Which type of the network should the customer define?

  • A. Tagged
  • B. Untagged
  • C. Internal
  • D. Tunnel

Answer: A

Explanation:
Virtual Connect will pass through all tagged packets without modification, and it will be the responsibility of the teaming software to strip/add tags.

 

NEW QUESTION 26
Which action is allowed on storage pools managed by HPE OneView?

  • A. Changing storage pool capacity
  • B. Setting storage pool replication
  • C. Changing storage pool RAID level
  • D. Volume provisioning

Answer: D

 

NEW QUESTION 27
You want to put two FlexNlCs into a single Link Aggregation Group within a server profile. What Is a prerequisite for this setup?

  • A. Both FlexNlCs must be connected to the same network.
  • B. The Compute Module profile must have exactly two connections defined.
  • C. The sFlow option must be enabled and configured.
  • D. An upgrade license must be purchased and deployed.

Answer: A

 

NEW QUESTION 28
What is required to add remote frame link topology to HPE OneView?

  • A. The HPE OneView certificate from the primary site must be added to HPE OneView in the remote site.
  • B. Multi-site licenses must be added to HPE OneView and activate for all available HPE Synergy frames.
  • C. Management ports of the remote frame link topology must be connected to the management LAN.
  • D. The IP address assigned to HPE Composer installed in a remote site must be registered in a primary site.

Answer: B

 

NEW QUESTION 29
Click the option that will prevent the appliance from sending any email notifications or forwarding any SNMP traps that are related to the server hardware.

Answer:

Explanation:

 

NEW QUESTION 30
Which statement about an HPE OneView server profile is true?

  • A. A server profile can be used to update firmware and drivers when the operating system on the server is up and running.
  • B. A server profile created for a specific server hardware type cannot be moved to a server with a different server hardware type.
  • C. A server profile can be created only for HPE BladeSystem, HPE Synergy, and HPE Superdome Flex servers.
  • D. A server profile can be used to configure a local storage controller, but cannot be used to configure SAN-based storage.

Answer: B

 

NEW QUESTION 31
Which statement about HPE OneView Global Dashboard is true?

  • A. It is an application that can be installed on Windows or Linux system that will provide automated discovery of HPE OneView instances
  • B. It is a plugin to HPE Oneview that will allow integration of HPE oneView with VMware management and monitoring components
  • C. It is a plugin to vCenter Server that will allow management of the components added to HPE Oneview from vCenter server interface
  • D. It is a virtual appliance that can aggregate health and inventory information from multiple HPE OneView appliances or HPE Composers

Answer: D

 

NEW QUESTION 32
Your workload profile in the BIOS. All of the servers are managed using HPE OneView.
How can this task be completed?

  • A. Set a specific workload profile for all managed servers as an HPE OneView global setting.
  • B. Set a specific workload profile using IL0 interface for each individual server.
  • C. Set a specific workload profile within Logical Interconnect Group and update all servers.
  • D. Set a specific workload profile within server profile template and update all profiles.

Answer: D

 

NEW QUESTION 33
You are deploying HPE OneView to manage a customer's HPE ProLiant servers Is this statement about appliance availability true?

  • A. During hpe oneView deployment customer may select configure proprietary HA mode.
  • B. HPE OneView availability relies on HA features provoed by the hypervisor
  • C. HPE OneView has a built-in HA feature that can be activated with an additional license
  • D. HA features for HPE OneView are enabled only if the appliance is deployed on an HPE SimpliVity cluster

Answer: B

 

NEW QUESTION 34
Refer to the exhibit.

You discovered that one of the profiles is not compliant with the server profile template. What could cause this profile to be inconsistent with the server profile template?

  • A. Changes to the server profile were implemented directly on the server profile.
  • B. The server was powered off or rebooted recently and IL0 did not reconnect to HPE OneView.
  • C. Network connectivity for HPE Synergy Compute Module was changed outside HPE OneView.
  • D. HPE OneView was restored from a backup that created ^consistency with the server profile template.

Answer: C

 

NEW QUESTION 35
A customer has to deploy 21 HPE Synergy Compute Modules in a boot from SAN setup. How this task can be simplified while keeping the profile consistent?

  • A. single SAN volume can be created and utilized by all HPE Synergy Compute Modules.
  • B. An existing volume can be replicated automatically when creating a server profile.
  • C. Boot volumes can be prepared in advance and later presented as shared volumes to the Compute Modules.
  • D. Boot volumes can be created on demand and defined in the server profile template.

Answer: D

 

NEW QUESTION 36
You want a server profile to be automatically applied when an HPE Synergy Compute Module is replaced.
Click the appropriate configuration option.

Answer:

Explanation:

 

NEW QUESTION 37
What is required to add remote frame link topology to HPE OneView?

  • A. Multi-site licenses must be added to HPE OneView and activate for all available HPE Synergy frames.
  • B. The HPE OneView certificate from the primary site must be added to HPE OneView in the remote site.
  • C. Management ports of the remote frame link topology must be connected to the management LAN.
  • D. The IP address assigned to HPE Composer installed in a remote site must be registered in a primary site.

Answer: C

 

NEW QUESTION 38
Which types of support dump can be created using HPE OneView? (Select two.)

  • A. Logical enclosure support dump
  • B. Firmware deployment support dump
  • C. Maintenance console support dump
  • D. Appliance support dump
  • E. Enclosure group support dump

Answer: A,D

 

NEW QUESTION 39
......

Get 100% Passing Success With True HPE2-T37 Exam: https://www.prep4sures.top/HPE2-T37-exam-dumps-torrent.html

Premium Quality HP HPE2-T37 Online dumps: https://drive.google.com/open?id=1x0PpzGdDNY-oJLTomyYvndylZz3YG_Wf