NEW QUESTION 33
Which two NetApp storage controllers would be used in a valid FlexPod Datacenter configuration? (Choose two.)

  • A. NetApp E2800
  • B. NetApp AFF A700
  • C. NetApp FAS2700
  • D. NetApp EF570

Answer: B,C

 

NEW QUESTION 34
A customer is planning to use a pair of MDS switches in a FlexPod design to host a few SAN workloads.
In this scenario, which two features should be enabled on the MDS switches for a successful configuration? (Choose two.)

  • A. fport-channel-trunk
  • B. NPV
  • C. port-channel-trunk
  • D. NPIV

Answer: C,D

 

NEW QUESTION 35
An architect is designing a FlexPod environment with Cisco Nexus 5000 switches to SAN boot all of the ESXi hosts over FC.
In this scenario, what should the LUN ID number be?

  • A. LUN 3
  • B. LUN 0
  • C. LUN 1
    Section: (none)
    Explanation
  • D. LUN 2

Answer: B

 

NEW QUESTION 36
Click the Exhibit button.

Referring to the exhibit, what is the name given to the link between the two Cisco Nexus switches?

  • A. vPC peer connection
  • B. vPC peer domain
  • C. vPC peer link
  • D. vPC Domain ID

Answer: C

 

NEW QUESTION 37
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)

  • A. service profiles
  • B. templates
  • C. boot from SAN
  • D. blade servers

Answer: A,D

Explanation:
Cisco introduced the idea of stateless computing with its blade server design.
A Cisco UCS instance allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature.
Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.

 

NEW QUESTION 38
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?

  • A. Reboot the CIMC on each server.
  • B. Remove the hard disks on each server.
  • C. Zero-out the FlexFlash cards on each server.
  • D. Reset the CIMC to the factory settings on each server.

Answer: D

Explanation:
On rare occasions, such as an issue with the current running firmware, troubleshooting a server may require you to reset the CIMC to the factory default. When this happens, all user-configurable settings are reset. This procedure is not part of the normal server maintenance. After you reset the CIMC, you are logged off and must log in again. You may also lose connectivity and may need to reconfigure the network settings.

 

NEW QUESTION 39
What are characteristics of the Cisco UCS 5108 blade chassis?

  • A. 6 RU, 6 half-width UCS B-series blades, 80 Gbps I/O bandwidth
  • B. 6 RU, 8 half-width UCS B-series blades, 160 Gbps I/O bandwidth
  • C. 4 RU, 8 half-width UCS B-series blades, 40 Gbps I/O bandwidth
  • D. 4 RU, 6 half-width UCS B-Series blades, 160 Gbps I/O bandwidth

Answer: B

 

NEW QUESTION 40
A FlexPod solution has been configured for iSCSI SAN boot with multiple paths between the server and the storage.
In this scenario, how many initiators (IQNs) per server will need to be added in the corresponding igroup in ONTAP?

  • A. one
  • B. four
  • C. two
  • D. three

Answer: B

Explanation:
The initator group REST API allows you to create, update, delete, and discover initiator groups, and add and remove initiators that can access the target and associated LUNs.

 

NEW QUESTION 41
A customer with a FlexPod Datacenter design that uses a 4-node FAS8200 for storage wants to add a new workload that requires high performance. The customer needs to nondisruptively move some workloads from the existing FAS system to the new storage.
Which storage system would satisfy the requirements?

  • A. FAS2700
  • B. AFF A300
  • C. E2700
  • D. EF570

Answer: D

 

NEW QUESTION 42
A customer with a FlexPod Express solution wants to enable remote access to the NetApp storage component.
In this scenario, which two access methods are recommended? (Choose two.)

  • A. RDP
  • B. Telnet
  • C. SSH
  • D. SAML

Answer: B,C

 

NEW QUESTION 43
A customer is investigating options for implementing a FlexPod Datacenter solution that is using vSphere 6.x.
In this scenario, which two resources would be important to review? (Choose two.)

  • A. NetApp Technical Report
  • B. Cisco Validated Design documents
  • C. Cisco Cloud Center documentation
  • D. VMware vSAN documentation

Answer: A,B

 

NEW QUESTION 44
A customer has verified physical connectivity on the FlexPod. However, the LUNs are not available on the Cisco UCS server. To make the LUNs visible to the UCS, the customer must enable a switching feature for zoning.
In this scenario, what should the customer do?

  • A. Enable the device connector feature in Cisco UCS Manager.
  • B. Enable Spine mode on all the Cisco Nexus 9000 switches.
  • C. Enable NPV on all switches.
  • D. Enable NPIV on all switches.

Answer: A

 

NEW QUESTION 45
A customer wants to extend a Layer 2 network over a Layer 3 Nexus 9000 infrastructure.
Which Layer 2 overlay scheme accomplishes this task?

  • A. EIGRP
  • B. STP
  • C. vPC
  • D. VXLAN

Answer: D

Explanation:
XLAN tunnels the Layer 2 network over the Layer.

 

NEW QUESTION 46
A customer has ordered a FlexPod Select solution with a NetApp EF570.
In this scenario, which three storage protocols are available for use? (Choose three.)

  • A. iSCSI
  • B. InfiniBand
  • C. NFS
  • D. FC
  • E. CIFS

Answer: C,D,E

 

NEW QUESTION 47
A customer wants to deploy FlexPod for a VDI solution with 10,000 users, each with 10 GB of storage allocated.
To support this configuration, which three components must be sized? (Choose three.)

  • A. the 1GbE ports from user systems
  • B. the Cisco UCS servers
  • C. the fabric interconnect ports
  • D. the optical cable length
  • E. the NetApp AFF storage

Answer: A,B,C

 

NEW QUESTION 48
Click the Exhibit button.

The total number of servers that a Cisco UCS Mini chassis supports is set to a maximum of how many hosts as shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 49
Click the Exhibit button.

You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?

  • A. two 8Gb HBAs
  • B. two 10GbE CNAs
  • C. two 1GbE NICs
  • D. two 10GbE NICs

Answer: D

 

NEW QUESTION 50
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?

  • A. uplink port
  • B. monitor port
  • C. appliance port
  • D. server port

Answer: A

 

NEW QUESTION 51
You are configuring a FlexPod system for NAS protocols. You want to ensure that there are multiple paths between the initiators and targets in the solution.
Which two steps will accomplish this task? (Choose two.)

  • A. Disable LACP.
  • B. Allow the VLANs over the vPC peer link.
  • C. Configure the VLANs in Cisco UCS Manager as Common/Global.
  • D. Configure the VSANs in the Cisco Nexus 5000 switches.

Answer: A,C

 

NEW QUESTION 52
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)

  • A. Red Hat
  • B. NetApp
  • C. Microsoft
  • D. Cisco
  • E. VMware

Answer: A,B,D

 

NEW QUESTION 53
Your customer wants assurances that all aspects of FlexPod are highly available.
Which statement is correct in this scenario?

  • A. Cisco UCS Manager maintains a replica of configuration information.
  • B. Cisco UCS Manager automatically copies its configuration data to a remote data store.
  • C. Cisco UCS Manager uses active-active architecture.
  • D. Cisco UCS Manager contains multiple UCS domains.

Answer: A

Explanation:
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies.

 

NEW QUESTION 54
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. Multipath mode
  • B. DualWire Management mode
  • C. Cluster mode
  • D. SingleConnect mode
  • E. Direct Connect mode

Answer: B,D,E

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 55
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?

  • A. MDS9148>show fcfwd
  • B. MDS9148>show fcc
  • C. MDS9148>show fcdomain
  • D. MDS9148>show flogi database

Answer: D

 

NEW QUESTION 56
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)

  • A. cluster interconnect switch
  • B. leaf switch
  • C. spine switch
  • D. core switch

Answer: B,C

 

NEW QUESTION 57
......


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager
Topic 2
  • Networking Hardware components, Configuration, High availability, SAN Boot
Topic 4
  • Storage Hardware components, Configuration, High availability, SAN Boot